E-light IPL Radio Frequency Skin Rejuvenation Machine

  • Description
Product Detail

    1.jpg

    2.jpg

    3.jpg

    4.jpg

    5.jpg

    ?Clinic operation?

    A. Before treatment

    To the machine:

    b). Input enough water and make good water circulation before actual operation

    c). Water source: distilled water or pure water

    d). Before the operation, make sure probe cold. Then it’s able to start the operation. (if take operation under the state of no water circulation or hot probe, the handpiece is easy to damaged.)

    e). Inflammable and explosive things should be kept away from operating room, such as stupefacient,liquid and gas.

    To the patients:

    a). Classification of skin: it's safe and effective to the white, brown or yellow skin.

    b). Clean skin to eliminate the perfume and cosmetics.

    c). Use digital camera for memory, take photo from different orientations, if necessary

    d). If necessary, use external anesthetic one hour before the treatment; Please shave hair firstly under hair removal treatment.

    f). Spread the cooling gel on skin, about 3 mm thickness

    g). Wear eyepatch before actual option

    Note: can not look at the intensive pulsed light directly, or alarm to people’s eyes, such as keratitis, cornea brushing off, or even lose sight.

    h). forbidden to wear watch and necklace etc. during the treatment.

    To the operators:

    a). Adjust the right parameters

    b). Touch the "Start" on the LCD

    c). Test the device working, please shot the 3 first pulse to ground at beginning,  make sure even energy output in treatment.

    d). Wear glasses before actual option

    e). forbidden to wear watch and necklace etc. during the treatment.

    f). can not look at the intensive pulsed light directly, or alarm to people’s eyes, such as keratitis,cornea brushing off, or even lose sight.

    g). Please do not optionally open the panel of the machine even power stopped, in case high voltage danger.

    h). It must tighten up the screw caps of machine before movement.

    i). vertically slide the probe on skin, and keep close to skin

    J). Keep the machine rest every 2-3 hours continuously working

    k). The handle is fragile, please keep special care when hanging to the holder or in handle

    l). Please do treatment from the lower energy at the beginning, and adjust the energy according to actual conditions.